即时比分网

Welcome to [Wuxi Yijin Machinery Co., Ltd.] official website!
Explosion-proof centrifugal fan

Position: 即时比分网 > Explosion-proof centrifugal fan

  • B4-72A explosion-proof centrifugal fan

    B4-72A explosion-proof centrifugal fan

    Click on the picture for details

  • B4-72C explosion-proof centrifugal fan

    B4-72C explosion-proof centrifugal fan

    Click on the picture for details

  • B4-72C explosion-proof centrifugal fan

    B4-72C explosion-proof centrifugal fan

    Click on the picture for details

  • FB9-12C explosion-proof centrifugal fan

    FB9-12C explosion-proof centrifugal fan

    Click on the picture for details

  • FB9-12C explosion-proof centrifugal fan

    FB9-12C explosion-proof centrifugal fan

    Click on the picture for details

  • FB9-12C explosion-proof centrifugal fan

    FB9-12C explosion-proof centrifugal fan

    Click on the picture for details

How is a centrifugal fan installed? The staff of the centrifugal fan manufacturer describes it as follows:
1. The installation of the centrifugal fan unit should be placed directly on the foundation and leveled with a pair of oblique horns.
2. For the centrifugal fan assembled on site, the cutting surface on the base should be properly protected from rust or operation. When the base is placed on the foundation, a pair of oblique horns should be used for leveling.
3. The bearing seat and the base should be tightly connected. The longitudinal non-horizontal degree should not exceed 0.2 / 1000. Measure with the spirit level on the main shaft. The horizontal non-horizontal bottom should not exceed 0.3 / 1000. Use the spirit level on the horizontal plane of the bearing seat. measuring.
4. Before grinding the bearing pads, first correct the rotor shaft centerline and the housing shaft centerline. At the same time, adjust the gap between the impeller and the air inlet and the gap between the main shaft and the shaft hole on the rear side of the casing to make it conform to the equipment technology. Documentation requirements.
5. When assembling the main shaft and the bearing bush, it should be inspected in accordance with the provisions of the equipment technical documents. The interference between the bearing cover and the bearing pad should be 0.03—0.04 mm.
6. When assembling the fan casing, the position of the casing should be aligned with the rotor axis line as the reference, and the axial and radial clearances between the impeller air inlet and the air inlet of the casing should be high speed within the specified range. Whether the anchor bolts are tight. If the gap value is not specified in the equipment technical documents, the general axial clearance should be 1/100 of the outer diameter of the impeller, and the radial clearance should be evenly distributed, and the value should be 1.5 / 1000-3 / 1000 of the outer diameter of the impeller. When adjusting, try to reduce the gap value to improve the efficiency of the fan.
7. When the fan is aligned, the different axiality of the fan shaft and the motor shaft: the radial positioning movement should not exceed 0.05 mm, and the tilt should not exceed 0.2 / 1000.
8. Centrifugal fans equipped with rolling bearings, different axial degrees of the bearing holes on the two bearing frames, after the rotor is installed, the rotation is flexible.